Engraved two-ply phenolic — not printed stickers or adhesive decals. Panel identification plates, circuit directories, and source-of-supply markings built to NEC 408.4 and your facility standard. Stocked in 28 color combinations, PMS color match on custom orders. Trusted for PG&E's panel identification work — engraved in Chico since 1982.

Request a quote Call (530) 895-8448
4.9 · 32 Google reviews
Engraved compliance placards produced by Recognition Products
24–48 HRS
Standard ship time
SAME-DAY RUSH
Available on request
LIVE PHONE
Real people. Always.
⚠ Placeholder — do not publish. Awaiting real industrial client quote.
"
Recognition Products has been our panel identification supplier for [X] years. Their engraved plates meet every spec our inspectors require, and their turnaround has never let us down — even on the emergency jobs.
— [Client name], [Title], [Company]
Engraved vs printed

Engraved to last. Not printed to peel.

"Electrical panel label" means different things to different buyers. Most products sold under that name are printed adhesive stickers — fine for temporary marking, but ink fades, adhesive fails, and NEC 408.4(B) prohibits handwritten identification and requires durability. We don't make stickers. We engrave two-ply phenolic plates.

The identification is cut into the material rather than printed on top of it. That construction is what puts our plates on PG&E service panels, hospital electrical rooms, and the switchgear our contractor customers install every week. Same 44 years of engraving compliance-grade identification in Chico.

Send us a drawing, a spec sheet, an existing plate, or just the panel numbers and legend — we come back with pricing, material recommendations, and a proof for your approval before anything ships. Reorders match the approved layout already on file.

What goes on the panel

Every plate on the panel, from cover to circuit.

The range of engraved plates that end up on a single electrical panel — each cut to your dimensions, engraved to your legend, and shipped ready to install.

Panel identification plates
The main plate that names the panel — "PANEL LP-1A," "MAIN DISTRIBUTION PANEL." Engraved to your drawing, cut to your dimensions, mounted to the enclosure face.
Facility spec
Circuit directory labels
Full engraved schedules identifying each circuit's purpose. Legibility per NEC 408.4(A), durability per NEC 408.4(B) — permanent, legible, not handwritten.
NEC 408.4(A)/(B)
Source-of-supply markings
Feeder and upstream disconnect identification per NEC 110.22. Tells the next technician where power comes from before they open the enclosure.
NEC 110.22
Disconnect identification
Legibly marked disconnecting means indicating purpose — engraved plates in any size, any legend, any two-ply color combination.
NEC 110.22
Breaker and device labels
Small engraved plates for individual breakers, contactors, or control devices inside the panel. Adhesive-back or drilled to spec.
Application-specific
Custom facility-standard plates
Your color rules, your legend format, your part-numbering convention. Send us your standard once and we match it on every reorder.
Facility spec
Materials we stock

Two-ply engravable phenolic, in the color your standard calls for.

Two-ply engravable laminate is the material we use for engraved panel labels — a colored cap layer over a contrasting core, so the legend appears when the cap is cut away. Flame-classified grades, nonconductive stock, and environmentally-compliant options available on request when your specification calls for them.

28
Stock color combinations. Plus PMS color match on custom orders.
We stock 28 different two-ply engravable laminate color combinations for standard identification and safety work. When your facility needs a specific branded color, we offer PMS color match on custom orders — sourced to your spec, engraved to your drawing.
ANSI Z535.4 safety colors
Signal Red (DANGER), Signal Orange (WARNING), Signal Yellow (CAUTION) with contrasting cores.
Standard identification colors
Black, white, red, blue, green, brown, yellow — the color palette for panel identification and equipment ID.
Flame-classified grades
Selected engraving laminates are available with manufacturer-published UL 94 classifications, including V-0 or HB at specified tested thicknesses. Availability and rating verified for the exact product, color, and thickness ordered.
Nonconductive stock
Selected engraving laminates are electrically nonconductive as described by their manufacturers. This does not constitute a dielectric or electrical-safety certification for the finished installation.
RoHS, PVC-free, formaldehyde-free grades
Environmentally-compliant grades available for facilities with restricted materials programs.
PMS color match on custom orders
Branded facility identification programs — we source PMS-matched engraving stock to your standard, engraved to your drawing.
Related guide
Not sure which material fits? Our engraving materials guide covers what each substrate suits, how it wears, and how to choose one for the environment the tag will live in.
Read the materials guide →
Built to your spec

The NEC references our panel labels are made against.

Current through NEC 2026 § 110.16 arc-flash expansion. Built to NFPA 70E-2024 § 130.5(H) durability standards. We manufacture to customer-provided content, drawings, adopted code editions, and facility specifications. We don't perform engineering studies, determine required hazard information, approve compliance, or act as the authority having jurisdiction — we make the label to your spec.

NEC 2023
§ 408.4(A) — Circuit identification
Every circuit shall be legibly identified as to its clear, evident, and specific purpose or use. Engraved directories satisfy legibility without depending on handwritten entries.
NEC 2023
§ 408.4(B) — Durable, not handwritten
Circuit identification shall be durable, legible, and not handwritten. Engraved two-ply phenolic meets the durability spec and the prohibition on handwritten identification.
NEC 2023
§ 110.22 — Disconnect identification
Each disconnecting means shall be legibly marked to indicate its purpose. Engraved feeder-ID and source-of-supply plates make the marking permanent.
NEC 2023
§ 110.21(B) — Field-applied marking
Markings must adequately warn, be permanently affixed, and have sufficient durability for the environment involved.
NEC · 2023 → 2026
§ 110.16 — Arc-flash hazard marking
2023 § 110.16(B) dropped the threshold from ≥1200A to ≥1000A on covered service and feeder-supplied equipment. 2026 removed the amperage threshold for detailed marking on service and feeder-supplied equipment in non-dwelling occupancies where energized examination or maintenance is required.
NFPA 70E · 2024
§ 130.5(H) — Arc flash equipment label
2024 edition added durability for the equipment environment. Equipment owner responsible for documentation, installation, and maintenance of the marked label.
ANSI Z535.4-2023
Signal-word formats
DANGER (white on Safety Red), WARNING (black on Safety Orange), CAUTION (black on Safety Yellow) — for panel plates that require signal-word hazard identification.
OSHA 29 CFR
§ 1910.303(f) — Disconnect identification
Each service, feeder, or branch-circuit disconnect shall be legibly marked to indicate its purpose. OSHA workplace requirement complementary to NEC.
Related guide
Working out what the code requires? Our electrical code compliance guide explains what the NEC, NFPA 70E, ANSI Z535.4, ASME A13.1 and OSHA 1910.147 ask of engraved identification — and where our responsibility begins and ends.
Read the code compliance guide →
Engraved electrical panel labeling trusted by teams at
Frequently asked

Common questions on engraved electrical panel labels.

What material do you use for panel labels?
Two-ply engravable laminate. A colored cap layer is bonded over a contrasting core, engraved so the legend appears in the core color. We stock 28 different color combinations and can custom-source PMS matches for facility programs. The identification is cut into the material, not printed on the surface.
What's the difference between engraved plates and printed labels?
Printed adhesive labels rely on ink or toner sitting on top of a substrate — UV, chemicals, heat, and cleaning cycles all degrade them over time, and adhesive fails. Engraved two-ply phenolic has the identification cut into the material rather than printed on top of it. NEC 408.4(B) prohibits handwritten circuit identification and requires durability, and engraved plates satisfy that requirement without depending on adhesive or ink. That's why buyers, inspectors, and AHJs specify engraved plates for permanent panel identification.
Do your circuit directory labels meet NEC 408.4?
Engraved two-ply phenolic meets the NEC 408.4(A) legibility requirement and the NEC 408.4(B) durability requirement, including the prohibition on handwritten identification. Compliance certification for the installed equipment remains the equipment owner's responsibility — we manufacture the label to your spec.
Can you match my facility's existing panel labels?
Yes. Send us a photo, a sample plate, or your facility standard. We match color combination, legend format, mounting method, and dimensions. Once we have your standard on file, reorders match exactly across every site and every reorder.
What colors are available?
28 two-ply color combinations in stock, including every ANSI safety color (Signal Red, Signal Orange, Signal Yellow) and standard identification colors (black, white, red, blue, green, brown, yellow). PMS color match available on custom orders for branded facility programs — sourced to your color standard, engraved to your drawing.
Can you handle source-of-supply and disconnect labels too?
Yes. Source-of-supply markings, feeder ID plates, and disconnecting-means identification per NEC 110.22 are all produced in the same materials and shop as panel schedules and circuit directories. Bundle them on one order — same 24–48 hour turnaround.
Do you handle multi-site or multi-location programs?
That's a specialty. Standardized templates, per-site variable data, consolidated billing, and consistent turnaround across every location. Currently supporting national and regional programs for utilities, contractors, and franchise operators.
What's the minimum order?
One. Order a single plate if that's what you need. Quantity discounts kick in on larger runs.
How fast can I get labels?
Standard turnaround is 24–48 hours from proof approval. Same-day rush is available for time-critical work. Faster on request when it's a real emergency — call and ask.
How do I order?
Send us a drawing, a spec sheet, an existing plate, or just the panel numbers and legend text. We come back with pricing, material recommendations, and a proof for your approval before anything ships. Reorders match the approved layout already on file. All calls answered live, Monday through Friday, 8:30 AM to 5:00 PM PT.

Get your engraved panel label quote in one call.

Send us your drawing, spec sheet, or existing plate — or just tell us the code and application. We'll come back with pricing, material recommendations, and a proof for your approval. Reorders match the approved layout already on file.